Mechanical and Electrical PE Sample Exams, Mechanical and Electrical PE Exam Technical study guides, Mechanical/Electrical design tools, Plumbing design tools and Quality control checklists.
This calculation can be done individually for each power cable that needs to be sized, or alternatively, it can be used to produce cable sizing waterfall charts for groups of cables with similar characteristics (e.g. cables installed on ladder feeding induction motors).
Considerations for Pneumatic Conveying Systems Design. 1. Bulk Density of the Material. Bulk density refers to the weight/volume of the product. In other words, it tells us how much 1 cuft volume of the product will weigh and is generally expressed in Pounds/Cubic Feet.
Planning to call a pro? The information here will make you a savvy homeowner that can discuss duct sizing with an HVAC professional, and you'll have a good sense of whether their calculations are accurate. If you decide to get professional guidance and ductwork estimates, use the Free Local Quotes option or the toll-free number on this …
Pump sizing, in many cases, is an afterthought. Many installers have a go-to pump that has been used for decades without fail.
Download scientific diagram | Diameter calculation for pure hydrogen pipeline as a function of pipeline inlet pressure. from publication: Thermodynamic and Technical Issues of Hydrogen and Methane ...
cable sizing calculation, step by step Example to calculate cable current, voltage drop and applying derating factors of installation
r measure just velocity pressure. Practically, velocity pressure is calculated by measuring pressure perpendicular to the air flow (Static Pressure) and also measuring pressure parallel. HVAC. to Size and Design DuctsM06-032Once you have these two values you can just subtract static pressure from the total pressure.
This open channel flow calculator will help you determine the water flow rate of open channels for any typical cross-sectional area of water flow.
We're a full-service Pneumatic Conveying company - from concept and design to engineering, fabrication, commissioning, and support.
Pipe sizes: Our engineers will allow you to select up to pipe sizes ranging from 2 inch to 14 inch in diameter. Alsıo we will select a single convey line size and the desired internal pipe diameter, the desired material convey rate, the piping …
As we saw in this application, sizing the pipe diameter to match pump discharge diameter resulted in a greater unit cost for pumping the process fluid.
Line sizing by the Process department is one of the most important and critical activities for any project. Line size is determined with proper sizing calculations considering various parameters.
Pipe Line sizing calculations is very important being a chemical engineer or project engineer or a piping engineer.In this article we study about how to #piping sizing calculations for steam, cooling water and air. In chemical industry we need to do line sizing for verius application like DM #water transfer, cooling water, solvent transfer etc.
Inlet control and outlet control are the two main approaches used for pipe culvert design. Either the flow rate through the culvert is controlled by the inlet to the pipe, or the flow rate through the culvert is controlled by the outlet from the culvert. Learn the equations to use when calculating design for both inlet and outlet.
To size a condensate line, follow these steps: Determine the condensate load: Calculate the amount of condensate generated by the system, usually expressed in kilograms per hour (kg/h) or pounds per hour …
Our pneumatic conveying line sizing calculation programs are … user to design a complete system, not just a conveying line pressure drop calculation. Request Quotation I am on the look out for system design calculation for lean phase and dense phase ...
Do you know how much stormwater runoff you need to manage, and what size and type of drain pipe to use? Use the NDS Drainage Calculator to get the results you need to help design a proper stormwater drainage system. The Drainage Calculator saves time with drainage calculations, and is available online and on the NDS Stormwater Drainage …
The formula to calculate this is: Pipe Diameter = √ (A*4/3.14) Where: Pa = Prevailing absolute pressure. Sea level is 14.7. Pd = compressor gauge pressure or psig. Example: Size a header for 500 SCFM at 100 PSI at an elevation at sea level. A = 144 x 500 x 14.7 / 30 x 60 (100 + 14.7) = 5.13 square inches.
Belt conveyors consist of two powered pulleys with a continuous loop of belting material used to convey products. Belt conveyors are the most economical powered conveyor and are typically used for conveying products over long distances, at high speeds, or for incline/decline applications. This is done with endless procession of hooks, gears, …
Back To Basics: Water Pipe Sizing. By Julius Ballanco P.E., CPD. November 1, 2007. It all revolves around a very basic equation to determine velocity and rate of flow. Editor's Note: "Back to Basics" is a column that will run periodically in PM Engineer reviewing the basic principles of plumbing engineering.
BL - Refrigerant Line Sizing App. Refrigerant Line Sizing. Units of Measurement: °F - ft - Btu/h °F - ft - ton °C - m - Btu/h °C - m - ton °C - m - W °C - m - kW. Evaporator Temp: Refrigerant: 12 134a 22 290 401A 404A 407A 407C 407F 408A 409A 410A 414B 422D 437A 438A 448A 449A 450A 452A 455A 502 507 513A. Refrigerant Line:
Calculate capacities and dimensions of natural gas pipe lines. The capacity of a low pressure natural gas (less than 1 psi, 6.9 kPa) pipe line with a small pressure loss can be calculated with the Spitzglass formula. q = 3550 k ( h / (l SG))1/2(1) where. q = natural gas volume flow (cfh) h = pressure drop (in Water Column) l = length of pipe ...
Utility line sizing calculator. Free online calculator developed by Engineering Page.
Many industry sectors use chain conveyor technology in their production lines. The automotive industry commonly uses chain conveyor systems to convey car parts through paint plants. Chain conveyors also have widespread use in the white and brown goods, metal finishing and distribution industries.
All of the above criteria is designed and selected by using the standard design calculations from the 'Pneumatic conveying system design guide' by David Mills. Thus for design calculations mainly two aspects about pneumatic conveying are used and they are.
This calculator determines the pressure drop of a compressible gas or vapour through a pipeline. The calculator can model isothermal and adiabatic flow. Compressible Line Sizing Calculator Guide Show Instructions The calculator determines the frictional pressure drop through a line assuming either isothermal or adiabatic compressible flow. The …
For a new pump, our calculations of Total Head for a given flow rate will have determined the impeller diameter to select according to the performance curve. Figure 4-4 shows only the information relevant to the 8 1/2" impeller performance curve.
The American Petroleum Institute (API) developed a standard in 1952, called API STD 2000, to address the tank blanket valve size requirements. The scope has not changed in 70 years, but parameters in the flow calculations have changed over time. In-breathing and out-breathing flow calculations are determined using the API 2000 Standard.
To design a dilute phase pneumatic conveying system with the air volume to convey your material, you must use mass calculations (that is, pounds of material per pound of air) while considering your installation location's ambient air temperature, humidity, and altitude.